I/O control of WIZ550web performs I/O control and monitoring using CGI. The web page is configured to obtain the status value (GET) of the web server or to transfer the changed value of the web page to the web server (POST) by utilizing the HTTP GET / POST method. In order to perform this operation, the HTML/JavaScript(AJAX) of the web page and the CGI handler of the web server must be implemented in a consistent manner. A description of CGI is provided in 'Getting Started Guide:CGI for WIZ550web'.

Users can understand and utilize I/O interface function implemented in WIZ550web through Tutorial. This allows users to access the Web server from a remote location, monitor the status of the user device, or create a user-specific WIZ550 web page that performs I/O on/off functions.

Tutorials

This tutorial covers the following topics:

    • It introduces the basic operation of Web browser and WIZ550web, and introduces predefined I / O interface function and test page so that user can modify web page and configure web site for desired form of I/O control.
    • This tutorial introduces the creation of a Web page that can control the On / Off state of Digital I/O (16) provided by WIZ550web. This allows the user to control the LED / Relay of the product via the web. You can also create Digital I/O Direction (Input/Output/None) control functions by applying the functions learned through this tutorial.

The specification for predefined I/O functions can be found in the following guide.



2017/05/15 11:28 · kei

Interface Functions Guide for WIZ550web

Overview


WIZ550web provides the HTTP Request function set for CGI so that device name and network setting, control and monitoring of each digital I/O and analog input can be performed only by making web page without modification of firmware.

It is implemented with GET/SET interface. By using JavaScript and AJAX to request CGI corresponding to each function with HTTP GET/POST method, user can easily implement web page that can control WIZ550web Can be.

In the case of a GET command, it is configured to obtain a value in the form of a JavaScript Callback function for the corresponding request. For the SET command, you can send the value you want to set to WIZ550web by including it in the HTTP request with the CGI request in the form of specified Web form element.

Please refer to 'Getting Started Guide:CGI for WIZ550web' for the CGI of WIZ550web.


Get/Set interface Web pages and firmware for testing using CGI can be downloaded from the following link.

WIZ550web GitHub Repository

https://github.com/Wiznet/WIZ550web

WIZ550web GitHub Repository: Webpage source code

GET/SET Interface functions Testpage

WIZ550web GET/SET Interface


The CGI list for the GET/SET interface of WIZ550web is shown below.

GET Function List

Get: Functions Table

HTTP Request
CGI name
Description
widget.cgi Get Basic Settings
io.cgi Get I/O all status, include pin 90,91 on-board LED
io_alias.cgi Get all I/O status. direction and port names
adc.cgi Get all ADC Status/values
get_devinfo.cgi Get Device info
get_netinfo.cgi Get Network info
get_serial_data.cgi Get serial data from buffer (Console port)
get_uart0info.cgi Get Serial port 0 settings (UART1, Console)
get_uart1info.cgi Get Serial port 1 settings (UART2, AT command)
get_dio0.cgi
~
get_dio15.cgi
Get I/O status per port
get_ain0.cgi
~
get_ain3.cgi
Get ADC info per port
Section CGI name JavaScript
Callback Parameter
Return Type Description Value (Example) Note
Device Information get_devinfo.cgi fwver String Firmware version 1.0.0 -
devname String Device name WIZ550web -
pcode String Product identifier 1-2-0 For WIZ configuration tool
mac String MAC address 00:08:DC:xx:xx:xx -
Network Information get_netinfo.cgi ip String IP address 192.168.11.2 -
gw String Gateway IP address 192.168.11.1 -
sub String Subnet Mask 255.255.255.0 -
dns String DNS server IP address 8.8.8.8 -
dhcp 1-digit number DHCP enable 0 or 1 1 : Enabled
0 : Disabled
Serial Port Information get_uart0info.cgi
get_uart1info.cgi
baud 1-digit number Baud rate 0 ~ 9 0:600
1:1200
2:2400
3:4800
4:9600
5:19200
6:38400
7:57600
8:115200
9:230400
databit 1-digit number Data bit 0 or 1 0:Databit8
1:Databit9
parity 1-digit number Parity bit 0 ~ 2 0:None
1:Odd
2:Even
stopbit 1-digit number Stopbit 0 or 1 0:Stopbit1
1:Stopbit2
flow 1-digit number Flow control 0 ~ 3 0:None
1:RTS/CTS
2:RS-422
3:RS-485
16-Digital I/O
(0 ~ 15)
get_dio0.cgi
~
get_dio15.cgi
dio_p 1 or 2-digit numbers I/O Pin Info. 0 -
dio_s 1-digit number I/O State 0 or 1 0 : Low
1 : High
dio_d 1-digit number I/O Direction 0/1/2 0 : NotUsed
1 : Input
2 : Output
dio_a String I/O Alias Digital I/O #0 -
4-Analog Inputs
(12-bit ADC)
get_ain0.cgi
~
get_ain3.cgi
ain_p 1-digit number Analog input pin 0 ~ 3 -
ain_v 1 ~ 4-digit numbers Analog input value 0 ~ 4095 The values need to transform for use.

Get: JavaScript Callback Function Name Table

HTTP Request
CGI name
JavaScript Function Name
on Web page
get_devinfo.cgi function DevinfoCallback(o)
get_netinfo.cgi function NetinfoCallback(o)
get_uart0info.cgi function UartinfoCallback(o)
get_uart1info.cgi
get_dio0.cgi
~
get_dio15.cgi
function DioCallback(o)
get_ain0.cgi
~
get_ain3.cgi
function AinCallback(o)

SET Function List

Set: Functions Table

HTTP Request
CGI name
Description
config.cgi Set Basic Settings for DemoPages
dout.cgi Set I/O port On/Off
save_alias.cgi Change name of I/O port
dir_change.cgi Change I/O direction
tx_serial_data.cgi Send serial data to UART1(Console port)
set_default_io_status.cgi IO Settings Factory Reset and Reboot
set_devinfo.cgi Set Device info (changes takes effect after reboot)
set_netinfo.cgi Set Network info (changes takes effect after reboot)
set_uart0info.cgi Set Serial port 0 settings (UART1, Console) (changes takes effect after reboot)
set_uart1info.cgi Set Serial port 1 settings (UART2, AT command) (changes takes effect after reboot)
set_diodir.cgi Change I/O direction. same as dir_change.cgi
set_diostate.cgi Set I/O port On/Off. almost the same as dout.cgi
set_dioalias.cgi Change name of I/O port. same as save_alias.cgi

config.cgi is for DemoPages.

Other common APIs are from set_devinfo.cgi

Section CGI name Parameter Webform Element Description Parameter Example Note
Device
Configuration
config.cgi devicename Param: String Device name devicename=WIZ550WEB -
dhcp Param: 0 or 1 DHCP enable dhcp=0 1 : Enabled
0 : Disabled
lib Param: Sting Local IP address lip=192.168.11.100 Including dots
gw Param: String Gateway IP address gw=192.168.11.254
sub Param: String Subnet Mask sub=255.255.255.192
dns Param: String DNS server IP address dns=168.126.63.1
baudrate Param: 1-digit number Baud rate baud=8 0:600
1:1200
2:2400
3:4800
4:9600
5:19200
6:38400
7:57600
8:115200
9:230400
databit Param: 8~9 Data bit databit=8 8:Databit8
9:Databit9
parity Param: 0~2 Parity bit parity=0 0:None
1:Odd
2:Even
stopbit Param: 1~2 Stopbit stopbit=1 1:Stopbit1
2:Stopbit2
flowcontrol Param: 0~3 Flow control flowcontrol=0 0:None
1:RTS/CTS
2:RS-422
3:RS-485
Device Information set_devinfo.cgi devname Param: String Device name devname=Server1 -
Network Information set_netinfo.cgi ip Param: String IP address ip= 192.168.11.3 Including dots
gw Param: String Gateway IP address gw= 192.168.11.254
sub Param: String Subnet Mask sub= 255.255.255.192
dns Param: String DNS server IP address dns= 168.126.63.1
dhcp Param: 0 or 1 DHCP enable dhcp=0 1 : Enabled
0 : Disabled
Serial Port Information set_uart0info.cgi
set_uart1info.cgi
baud Param: 1-digit number Baud rate baud=8 0:600
1:1200
2:2400
3:4800
4:9600
5:19200
6:38400
7:57600
8:115200
9:230400
databit Param: 8~9 Data bit databit=8 8:Databit8
9:Databit9
parity Param: 0~2 Parity bit parity=0 0:None
1:Odd
2:Even
stopbit Param: 1~2 Stopbit stopbit=1 1:Stopbit1
2:Stopbit2
flow Param: 0~3 Flow control flow=0 0:None
1:RTS/CTS
2:RS-422
3:RS-485
16-Digital I/O
(0 ~ 15)
set_diostate.cgi pin / val Params: digit numbers I/O State pin=0&val=1 pin:0~15
val=0(Low/On)
val=1(High/Off)
set_diodir.cgi pin / val I/O Direction pin=1&val=2 pin:0~15
val=0(Not used)
val=1(Input)
val=2(Output)
set_dioalias.cgi pin / val Params: digit numbers / String I/O Alias pin=1&val=pin#1 pin:0~15