Supported Languages
* This section was written on the assumption that the use of WIZ750SR-105-EVB evaluation board.
Figure: WIZ750SR-105 Rev. 1.0 Evaluation Board Package |
---|
The WIZ750SR-105 evaluation board package contains the following parts.
The entire list of parts of the board is available at the WIZ750SR-105 Overview: Product Contents page.
Network Settings | Local | IP address | 192.168.11.2 | - |
---|---|---|---|---|
Gateway address | 192.168.11.1 | - | ||
Subnet mask | 255.255.255.0 | - | ||
DNS server | 8.8.8.8 | Google Public DNS | ||
Port number | 5000 | - | ||
Remote | IP address | 192.168.11.3 | - | |
Port number | 5000 | - |
Serial Port Settings | Data UART | 115200-8-N-1 / Flow Control: None | - |
---|---|---|---|
Debug UART | 115200-8-N-1 / Flow Control: None | Fixed |
User's I/O Settings | UserIO A | Analog / Input | Read only |
---|---|---|---|
UserIO B | Digital / Input | Read only | |
UserIO C | Digital / Output | Read / Write | |
UserIO D | Digital / Output | Read / Write |
Double check that the WIZ750SR-105 and the PC, or laptop you are using to set up WIZ750SR-105 with are both on the same Ethernet network.
* When the WIZ750SR-105's settings are factory default,
Network Settings | PC or laptop (= Remote) | IP address | 192.168.11.3 | - |
---|---|---|---|---|
Gateway address | 192.168.11.1 | - | ||
Subnet mask | 255.255.255.0 | - | ||
Port number | 5000 | - |
The WIZ750SR-105-EVB is designed to use the DB9 connector to connect with the user’s serial device. Therefore, it is recommended to have all Ethernet and serial ports connected to the PC when testing. If the PC does not have a serial port, please purchase a RS-232 to USB converter separately.
Connect the WIZ750SR-105 module to evaluation board and also the cable as shown in the picture below.
Figure: Combining WIZ750SR-105 module and EVB |
---|
Figure: WIZ750SR-105-EVB side view |
---|
Connect the 5V power adaptor or USB cable to the evaluation board and turn on the power switch.
Open the configuration tool and click the search button. If the board is turned on and connected to the same network, the MAC address or settings of the WIZ750SR-105 module can be checked using the configuration tool.
Change the settings accordingly to the customer’s environment. The test shown in this document is based on factory setting.
Connect the PC as the TCP client of the user’s serial device for data communication testing. In order to do this, the serial terminal program / TCP client terminal program must be opened on the PC. The serial terminal program and TCP client program must be set as below.
The COM port for serial terminal program connection can be checked as below.
The basic data communication of the WIZ750SR-105 can be verified as below.
Now you’re ready to use the WIZ750SR-105!
If there is any problem?
Please refer to our Troubleshooting Guide!